Skip to content
GIRIVON
Infrastructure+
Systems+
Components+
Computing Devices+
Solutions+
Compute Tools+
Knowledge+

RAID & Storage Capacity Calculator

Compare RAID levels for a set of drives: usable capacity in TB and TiB, efficiency, how many drive failures each survives, theoretical read/write throughput and IOPS with write penalties, and rebuild time.

Results

Usable capacity
200 TB
Usable capacity (binary)
181.9 TiB
Efficiency
83%
Drive failures tolerated
2
Sequential read
3,000 MB/s
Sequential write
2,500 MB/s
Random read IOPS
2,160
Random write IOPSWrite penalty 6
360
Rebuild time (one drive)
2.3 days

RAID is not a backup: it protects against drive failure, not deletion, corruption or site loss.

What it calculates

  • Usable capacity (TB / TiB)
  • Storage efficiency
  • Fault tolerance
  • Theoretical throughput and IOPS
  • Rebuild time

Worked example

Using the default inputs below; change any input above to recalculate.

Inputs
Drives12
Drive capacity20 TB
RAID levelRAID 6 / RAID-Z2 (double parity)
Groups (RAID 50/60 only)2
Hot spares0
Sequential throughput per drive250 MB/s
Random IOPS per drive180
Rebuild rate100 MB/s
Results
Usable capacity200 TBcalculated
Usable capacity (binary)181.9 TiBcalculated
Efficiency83%calculated
Drive failures tolerated2calculated
Sequential read3,000 MB/stheoretical
Sequential write2,500 MB/stheoretical
Random read IOPS2,160theoretical
Random write IOPS360theoretical
Rebuild time (one drive)2.3 daysestimated

Methodology

Usable capacity counts data drives: all for RAID 0, one for RAID 1, n − 1 for RAID 5, n − 2 for RAID 6, n/2 for RAID 10, and per-group parity for RAID 50/60. Drive vendors use decimal terabytes; operating systems often show binary TiB.

Random write IOPS divide raw IOPS by the write penalty — the disk operations per logical write: 1 (RAID 0), 2 (mirrors), 4 (single parity), 6 (double parity). Rebuild time is drive capacity ÷ rebuild rate.

Formulas

RAID 6
usable = (n − 2) × size
Write IOPS
IOPS_w = n × IOPS_drive ÷ penalty
Rebuild
t = size ÷ rebuild_rate

Assumptions

  • Identical drives; full-stripe writes for sequential write estimates.

Limitations

  • Controller cache, SSD behaviour and filesystem overheads change real performance.
  • ZFS RAID-Z capacity also depends on record size and padding.