RAID & Storage Capacity Calculator
Compare RAID levels for a set of drives: usable capacity in TB and TiB, efficiency, how many drive failures each survives, theoretical read/write throughput and IOPS with write penalties, and rebuild time.
Results
- Usable capacity
- 200 TBcalculated
- Usable capacity (binary)
- 181.9 TiBcalculated
- Efficiency
- 83%calculated
- Drive failures tolerated
- 2calculated
- Sequential read
- 3,000 MB/stheoretical
- Sequential write
- 2,500 MB/stheoretical
- Random read IOPS
- 2,160theoretical
- Random write IOPSWrite penalty 6
- 360theoretical
- Rebuild time (one drive)
- 2.3 daysestimated
RAID is not a backup: it protects against drive failure, not deletion, corruption or site loss.
What it calculates
- Usable capacity (TB / TiB)
- Storage efficiency
- Fault tolerance
- Theoretical throughput and IOPS
- Rebuild time
Worked example
Using the default inputs below; change any input above to recalculate.
| Drives | 12 |
|---|---|
| Drive capacity | 20 TB |
| RAID level | RAID 6 / RAID-Z2 (double parity) |
| Groups (RAID 50/60 only) | 2 |
| Hot spares | 0 |
| Sequential throughput per drive | 250 MB/s |
| Random IOPS per drive | 180 |
| Rebuild rate | 100 MB/s |
| Usable capacity | 200 TB | calculated |
|---|---|---|
| Usable capacity (binary) | 181.9 TiB | calculated |
| Efficiency | 83% | calculated |
| Drive failures tolerated | 2 | calculated |
| Sequential read | 3,000 MB/s | theoretical |
| Sequential write | 2,500 MB/s | theoretical |
| Random read IOPS | 2,160 | theoretical |
| Random write IOPS | 360 | theoretical |
| Rebuild time (one drive) | 2.3 days | estimated |
Methodology
Usable capacity counts data drives: all for RAID 0, one for RAID 1, n − 1 for RAID 5, n − 2 for RAID 6, n/2 for RAID 10, and per-group parity for RAID 50/60. Drive vendors use decimal terabytes; operating systems often show binary TiB.
Random write IOPS divide raw IOPS by the write penalty — the disk operations per logical write: 1 (RAID 0), 2 (mirrors), 4 (single parity), 6 (double parity). Rebuild time is drive capacity ÷ rebuild rate.
Formulas
- RAID 6
- usable = (n − 2) × size
- Write IOPS
- IOPS_w = n × IOPS_drive ÷ penalty
- Rebuild
- t = size ÷ rebuild_rate
Assumptions
- Identical drives; full-stripe writes for sequential write estimates.
Limitations
- Controller cache, SSD behaviour and filesystem overheads change real performance.
- ZFS RAID-Z capacity also depends on record size and padding.