Add up component power for a workstation or server, estimate sustained and transient peak load, size the power supply with headroom (including N+1 redundant supplies) and work out wall power, heat and electricity cost.

Compute
Platform

Estimate; DDR5 RDIMMs commonly draw several watts each under load.

Sizing

Short power excursions above board power; ATX 3.x supplies are specified to tolerate brief excursions.

Energy

Results

CPU + GPU power
950 W
Sustained DC load
1,114 W
Transient peak
1,294 W
Recommended PSU
1,500 W
Load on PSU at sustained
74%
Wall power at sustained92% efficiency assumed
1,211 W
Heat output
4,132 BTU/h
Annual energy
7,425 kWh
Annual electricity cost
₹59,400

What it calculates

  • Sustained DC load
  • Transient peak
  • Recommended PSU size
  • Wall power
  • Heat output
  • Annual energy and cost

Worked example

Using the default inputs below; change any input above to recalculate.

Inputs
CPUs1
Power per CPU (TDP / PPT)350 W
GPUs2
Board power per GPU300 W
Memory modules8
Power per module6 W
NVMe SSDs2
Hard drives0
Add-in NICs / DPUs1
Motherboard, fans and other80 W
GPU transient peak factor1.3
Target PSU load at sustained power80 %
PSU efficiency rating80 PLUS Platinum
Redundant supplies (N+1)No
Results
CPU + GPU power950 Wcalculated
Sustained DC load1,114 Westimated
Transient peak1,294 Westimated
Recommended PSU1,500 Wcalculated
Load on PSU at sustained74%calculated
Wall power at sustained1,211 Westimated
Heat output4,132 BTU/hcalculated
Annual energy7,425 kWhestimated
Annual electricity cost₹59,400estimated

Methodology

Sustained load is the sum of component power: CPU and GPU from their rated power, plus estimates for memory, drives (≈8 W each), NICs (≈20 W each) and the platform. GPU transient peaks are modelled with a multiplier on GPU power.

The PSU must satisfy both the sustained load at your target loading (80% leaves headroom and keeps the supply near its efficient range) and the transient peak; the result is rounded up to common supply sizes. In N+1 redundancy every supply must carry the full load alone.

Wall power divides DC load by the efficiency of the 80 PLUS level at 50% load (115 V internal: Bronze 85%, Silver 88%, Gold 90%, Platinum 92%, Titanium 94%).

Formulas

PSU
PSU ≥ max(P_sustained ÷ target_load, P_peak)
Wall
P_wall = P_DC ÷ η
Heat
BTU/h = W × 3.412

Assumptions

  • Drive and NIC power are typical estimates.
  • Efficiency taken at the 80 PLUS 50%-load level.

Limitations

  • CPU boost behaviour can exceed TDP for minutes at a time.
  • Efficiency varies with input voltage and load.