System Power & PSU Calculator
Add up component power for a workstation or server, estimate sustained and transient peak load, size the power supply with headroom (including N+1 redundant supplies) and work out wall power, heat and electricity cost.
Results
- CPU + GPU power
- 950 Wcalculated
- Sustained DC load
- 1,114 Westimated
- Transient peak
- 1,294 Westimated
- Recommended PSU
- 1,500 Wcalculated
- Load on PSU at sustained
- 74%calculated
- Wall power at sustained92% efficiency assumed
- 1,211 Westimated
- Heat output
- 4,132 BTU/hcalculated
- Annual energy
- 7,425 kWhestimated
- Annual electricity cost
- ₹59,400estimated
What it calculates
- Sustained DC load
- Transient peak
- Recommended PSU size
- Wall power
- Heat output
- Annual energy and cost
Worked example
Using the default inputs below; change any input above to recalculate.
| CPUs | 1 |
|---|---|
| Power per CPU (TDP / PPT) | 350 W |
| GPUs | 2 |
| Board power per GPU | 300 W |
| Memory modules | 8 |
| Power per module | 6 W |
| NVMe SSDs | 2 |
| Hard drives | 0 |
| Add-in NICs / DPUs | 1 |
| Motherboard, fans and other | 80 W |
| GPU transient peak factor | 1.3 |
| Target PSU load at sustained power | 80 % |
| PSU efficiency rating | 80 PLUS Platinum |
| Redundant supplies (N+1) | No |
| CPU + GPU power | 950 W | calculated |
|---|---|---|
| Sustained DC load | 1,114 W | estimated |
| Transient peak | 1,294 W | estimated |
| Recommended PSU | 1,500 W | calculated |
| Load on PSU at sustained | 74% | calculated |
| Wall power at sustained | 1,211 W | estimated |
| Heat output | 4,132 BTU/h | calculated |
| Annual energy | 7,425 kWh | estimated |
| Annual electricity cost | ₹59,400 | estimated |
Methodology
Sustained load is the sum of component power: CPU and GPU from their rated power, plus estimates for memory, drives (≈8 W each), NICs (≈20 W each) and the platform. GPU transient peaks are modelled with a multiplier on GPU power.
The PSU must satisfy both the sustained load at your target loading (80% leaves headroom and keeps the supply near its efficient range) and the transient peak; the result is rounded up to common supply sizes. In N+1 redundancy every supply must carry the full load alone.
Wall power divides DC load by the efficiency of the 80 PLUS level at 50% load (115 V internal: Bronze 85%, Silver 88%, Gold 90%, Platinum 92%, Titanium 94%).
Formulas
- PSU
- PSU ≥ max(P_sustained ÷ target_load, P_peak)
- Wall
- P_wall = P_DC ÷ η
- Heat
- BTU/h = W × 3.412
Assumptions
- Drive and NIC power are typical estimates.
- Efficiency taken at the 80 PLUS 50%-load level.
Limitations
- CPU boost behaviour can exceed TDP for minutes at a time.
- Efficiency varies with input voltage and load.